NEW QUESTION 38
What is the recommended thickness for plywood that will be mounted on the walls of a telecommunications room?

  • A. 25 mm (1")
  • B. 19 mm (3/4")
  • C. 12.7 mm (1/2")
  • D. 32 mm (1-1/4")

Answer: B

 

NEW QUESTION 39
You are pre-terminating cable. Where should the labels be placed?

  • A. Both ends
  • B. Far end
  • C. Near end

Answer: A

 

NEW QUESTION 40
A purple backboard should be used to identify ________?

  • A. Demarcation point
  • B. Common equipment
  • C. Network connections
  • D. Horizontal cable

Answer: B

 

NEW QUESTION 41
Which of the following types of construction protects the optical fiber by supporting each strand of glass with a buffer coating extruded over the base optical fiber's 250 um acrylate coating?

  • A. Single stranded
  • B. Loose tube
  • C. Ribbon
  • D. Tight buffered

Answer: D

 

NEW QUESTION 42
A grey backboard should be used to identify _____ backbone cable?

  • A. First-level
  • B. Second-level
  • C. Intrabuilding

Answer: B

 

NEW QUESTION 43
Which of the following refers to a set of rules issued by a governmental body at the state level within the US?

  • A. Regulations
  • B. Best Practices
  • C. Applications
  • D. Guidelines

Answer: A

 

NEW QUESTION 44
Which of the following is a floor serving space that serves as a point of termination for horizontal and backbone cables?

  • A. TE
  • B. EF
  • C. ER
  • D. TR

Answer: D

 

NEW QUESTION 45
What is the bend radius requirement for optical fiber cable when the cable is at rest?

  • A. 10 times the cables outside diameter
  • B. 15 times the cables outside diameter
  • C. 20 times the cables outside diameter

Answer: A

 

NEW QUESTION 46
What type of connector is used with ribbon cable?

  • A. MPO
  • B. Array
  • C. F Connector
  • D. N Connector

Answer: B

 

NEW QUESTION 47
Which of the following fire ratings refers to the time period that a fire-rated assembly can resist flame passage?

  • A. F rating
  • B. L rating
  • C. W rating
  • D. T rating

Answer: A

 

NEW QUESTION 48
What is the characteristic impedance of Series-6 coaxial cable?

  • A. 25 ohms
  • B. 100 ohms
  • C. 50 ohms
  • D. 75 ohms

Answer: D

 

NEW QUESTION 49
What is the minimum recommended height that should be used when mounting a plywood back board in a telecommunication space?

  • A. AFF 200 mm (8")
  • B. AFF 300 mm (12") AFF
  • C. AFF 150 mm (6")
  • D. 100 mm (4")

Answer: A

 

NEW QUESTION 50
Which of the following results from the different optical path lengths in a multimode fiber?

  • A. Chromatic dispersion
  • B. Modal dispersion
  • C. Attenuation

Answer: B

 

NEW QUESTION 51
What is the primary purpose of the telecommunications bonding infrastructure?

  • A. Improve the performance of the installed telecommunications equipment
  • B. Equalize potentials between metallic surfaces and equipment within entrance facilities
  • C. Provide backup power to the telecommunications equipment when primary power to the equipment fails.

Answer: B

 

NEW QUESTION 52
How much sheath of the cable needs to be removed in order to properly terminate an 8P8C?

  • A. 6.3mm (0.25")
  • B. 38 mm (1.5")
  • C. 25mm (1")
  • D. 12.7mm (0.5")

Answer: D

 

NEW QUESTION 53
Which of the following steps should be performed first when an installer is pulling backbone cable from the bottom up?

  • A. Move cable reels into place
  • B. Label cables and reels
  • C. Determine appropriate rope size
  • D. Verify the proper cable run

Answer: D

 

NEW QUESTION 54
Which of the following fire ratings refers to the time period that the unexposed surface of a firestop assembly does not exceed 180 degrees C (325 degrees F) above its initial temperature?

  • A. FH rating
  • B. S rating
  • C. E rating
  • D. FT rating

Answer: D

 

NEW QUESTION 55
A category 8 cable is terminated into category 6A outlets with category 5e patch cords. What is the maximum supported performance level?

  • A. Category 6A
  • B. Category 8
  • C. Category 5e
  • D. Category 7

Answer: C

 

NEW QUESTION 56
Which of the following is permissible if the available firestop assembly is NOT capable of properly restoring the necessary fire rating?

  • A. Substitute products from another assembly
  • B. Add more of the product to increase the rating
  • C. Move the installation to another location
  • D. Obtain written assistance from the manufacturer

Answer: D

 

NEW QUESTION 57
Which of the following terms is used to describe mechanical firestop systems?

  • A. Ablative
  • B. Elastomeric
  • C. Intumescent
  • D. Endothermic

Answer: B

 

NEW QUESTION 58
Which of the following steps should be performed first when an installer is pulling optical fiber cable?

  • A. Label cables
  • B. Ensure the cable has been tested and accepted
  • C. Install and secure innerduct
  • D. Attach pull rope

Answer: B

 

NEW QUESTION 59
A radio station transmits an omnidirectional signal that is received by multiple radios. What type of transmission method is used in this example?

  • A. Simplex
  • B. Half-duplex
  • C. Full-duplex

Answer: A

 

NEW QUESTION 60
......